While --with-poller configure option could be used for selecting
the polling mechanism for I/O threads (asynchronous), synchronous
polling (xs_poll, signaler_t) was not affected by the option.
This patch uses selected mechanism is it is either 'select' or 'poll'.
Othrwise it chooses the mechanism according to the platform.
Signed-off-by: Martin Sustrik <sustrik@250bpm.com>
|
|
Signed-off-by: Martin Sustrik <sustrik@250bpm.com>
|
|
Originally, the parameter was of type long which is incompatible
with POSIX poll() function.
Signed-off-by: Martin Sustrik <sustrik@250bpm.com>
|
|
Signed-off-by: Martin Sustrik <sustrik@250bpm.com>
|
|
The timeout should be int. For historical reasons, however,
it is defined as long. To fix the problem the value is
checked in the runtime to assure it is not larger than INT_MAX.
Signed-off-by: Martin Sustrik <sustrik@250bpm.com>
|
|
Signed-off-by: Martin Sustrik <sustrik@250bpm.com>
|